Pure Storage FlashArray Implementation Specialist Free Sample Questions

Covers site readiness and pre-installation validation, hardware install and software configuration, hardware and software upgrade procedures and capacity consolidation, and post-upgrade verification.

20 free sample questions246 in the full practice test

Try simulator

FAIS Sample Questions

  1. Question 1

    A financial services firm is upgrading their FlashArray//X70R2 to an //X70R4. The upgrade plan involves a chassis swap while keeping the original DirectFlash Modules (DFMs). During the pre-upgrade validation, the implementation specialist notes the existing array is running a Purity version that is not the required minimum for the R4 chassis. What is the correct sequence of operations to ensure a successful, non-disruptive upgrade?

    Answer and explanation

    Correct answer: B

    The correct procedure is to first bring the software to a compatible level before introducing new hardware. The Purity//FA software on the existing R2 chassis must be upgraded to the minimum version that supports the R4 hardware before the physical chassis swap occurs. Attempting to bring up the R4 chassis with an unsupported Purity version on the DFMs will result in failure. Upgrading after the swap is not possible if the controllers cannot boot with the old software version.

  2. Question 2

    During a new FlashArray//C60 installation, an engineer successfully racks and cables the array. Upon powering on, the controllers boot, but the initial setup wizard does not start, and the management ports are unresponsive. The engineer connects via the serial console and observes messages indicating a 'shelf mismatch' error. What is the MOST likely cause of this issue?

    Answer and explanation

    Correct answer: B

    A 'shelf mismatch' error during initial boot often indicates an improper SAS cabling connection between the controllers and the expansion shelves. Reversing the SAS cables (e.g., connecting a controller's 'out' port to another controller's 'in' port, or mis-cabling the shelf loop) is a common installation error that would prevent the controllers from correctly discovering and identifying the attached shelves, thus halting the setup process.

  3. Question 3

    An implementation specialist is validating an Implementation Workbook (IWB) for a new FlashArray deployment. The customer's network team has provided a single IP address for the replication network, but the IWB specifies configuring two replication interfaces (rep0, rep1) on separate subnets for redundancy. What is the most appropriate first action for the specialist?

    Answer and explanation

    Correct answer: C

    The correct action is to proactively address the discrepancy between the customer's provisioned resources and Pure Storage's best practices. The specialist should communicate the need for a second, separate IP address and subnet for the second replication interface to ensure high availability and prevent a single point of failure in the replication network. Proceeding with a non-redundant configuration would be a disservice to the customer.

  4. Question 4

    Multiple answers

    A hospital is implementing a new FlashArray//XL for its Electronic Health Record (EHR) system. Due to the critical nature of the data, they have requested ActiveCluster be configured between the new array and an existing FlashArray//X in a secondary data center. Which TWO of the following are mandatory prerequisites for a successful ActiveCluster implementation? (Select TWO)

    Answer and explanation

    Correct answers: A, C

  5. Question 5

    True or False: When performing a capacity consolidation on a FlashArray that involves replacing smaller capacity data packs with larger ones, a data evacuation to another array is always required.

    Answer and explanation

    Correct answer: B

    This statement is false. While data evacuation is one method, it is not always required. If the FlashArray has sufficient free space and available drive slots, capacity consolidation can often be performed non-disruptively by adding the new, larger data packs, allowing Purity to rebalance data onto them, and then removing the older, smaller data packs one by one. A data evacuation is typically only necessary in scenarios with very high capacity utilization or when a full chassis swap is required.

  6. Question 6

    After successfully installing a new FlashArray, the implementation specialist is performing the final verification steps. The customer wants to ensure that Pure Storage Support can receive automatic diagnostic data. Which command should the specialist run from the Purity CLI to verify that the phone-home functionality is correctly configured and operational?

    Answer and explanation

    Correct answer: C

    The purearray phonehome --test command is the specific Purity CLI tool used to send a test transmission to Pure Storage Support. A successful result from this command confirms that the array's network configuration, firewall rules, and phone-home settings are all correct, and that diagnostic data can be sent successfully.

  7. Question 7

    A consultant is performing a site readiness check for a FlashArray//E installation. The data center uses a raised floor environment for cooling and power distribution. Which environmental factor is MOST critical to verify for the FlashArray//E model specifically, compared to other FlashArray models?

    Answer and explanation

    Correct answer: B

    The FlashArray//E is designed for high capacity and is significantly heavier than other models. Verifying the rack's load rating, as well as the load-bearing capacity of the raised floor tiles beneath it, is the most critical factor. Failure to do so could result in damage to the equipment or the data center infrastructure. While power and cooling are important for all models, the exceptional weight of a fully populated //E chassis makes structural support the primary concern.

  8. Question 8

    Case Study:

    A mid-sized e-commerce company is migrating its primary database environment to a new FlashArray//X50R4. The implementation plan requires connecting the array to a Cisco SAN fabric. The company has a strict security policy that mandates the use of port zoning on the fabric switches to ensure servers can only see their designated LUNs.

    The implementation engineer has physically cabled the array's Fibre Channel ports (fc0, fc1 on each controller) to the Cisco switches. After configuring the array, creating a volume, and connecting it to a host group, the database administrator reports that the host cannot see the new storage. The engineer verifies the host's HBA WWPN is correct in the host object on the array.

    Upon inspecting the Cisco switch, the engineer finds that a zone has been created containing the host's WWPN and the array's WWPNs. However, the host still cannot see the LUNs. The engineer suspects an issue with how the array's ports are being presented to the fabric.

    What is the most likely cause of the connectivity issue?

    Answer and explanation

    Correct answer: C

    Pure Storage FlashArrays require N_Port ID Virtualization (NPIV) to be enabled on the SAN fabric switches. NPIV allows a single physical Fibre Channel port to register multiple WWPNs on the fabric, which is how the FlashArray presents itself. If NPIV is disabled, the switch will only recognize the physical port's WWN and not the virtual WWNs used for host communication, leading to the exact symptom described: the host and array are in a zone, but LUN masking fails because the correct target ports are not visible. Verifying and enabling NPIV is a critical step in troubleshooting this type of connectivity issue.

  9. Question 9

    When racking a new FlashArray//X chassis, what is the vendor-recommended best practice for placement within the rack to ensure optimal stability and serviceability?

    Answer and explanation

    Correct answer: C

    The industry-standard and vendor-recommended best practice is to install the heaviest equipment at the bottom of the rack. This provides the lowest center of gravity, ensuring maximum stability and preventing the rack from becoming top-heavy and posing a tipping hazard. The FlashArray chassis should be installed first, at the bottom, followed by any expansion shelves above it.

  10. Question 10

    During a customer handoff meeting after a successful installation, the storage administrator asks for a simple way to demonstrate the array's data reduction capabilities. Which action provides the MOST direct and effective demonstration using the Purity GUI?

    Answer and explanation

    Correct answer: B

    The most effective way to demonstrate data reduction is to use a data set that is known to be highly compressible. Copying a VDI gold image or a text-based database export to a new volume will quickly result in a high data reduction ratio. The overall 'Data Reduction' number on the Purity Dashboard is the most prominent and easily understood metric to show the customer, as it reflects the total efficiency of the array.