  1. Question 1

    A storage administrator is commissioning a new Huawei OceanStor Dorado 6800 V6 array. During the network planning phase, the administrator must configure both management and service network ports. The security policy requires complete isolation between management traffic and iSCSI service traffic. Which action is essential to meet this requirement?

    Answer and explanation

    Correct answer: C

    To ensure complete traffic isolation for security and performance, management network traffic should be logically or physically separated from service (data) traffic. The best practice is to use different VLANs or entirely separate physical network switches. Assigning IPs from the same subnet or bonding ports would merge the traffic, violating the security requirement.

  2. Question 2

    A system administrator is investigating a performance degradation issue on a VMware vSphere environment connected to a Huawei OceanStor 5500 V6 hybrid array. Latency for a key virtual machine has suddenly increased. Analysis using DeviceManager shows that the storage pool's read cache hit ratio is below 10%, while disk utilization is consistently high. Which Huawei feature should be configured to most effectively address this read performance bottleneck?

    Answer and explanation

    Correct answer: C

    The scenario describes a classic read performance bottleneck characterized by a low read cache hit ratio, forcing reads to come from slower disks (high disk utilization). SmartCache is specifically designed to address this by using SSDs as a large secondary read cache. This increases the cache hit ratio for read-intensive workloads and reduces latency. SmartTier moves data chunks, which is a slower process, while SmartQoS manages I/O priority, which doesn't solve the underlying cache miss problem.

  3. Question 3

    A server administrator reports that a newly provisioned Linux server cannot see its assigned LUN from a Huawei OceanStor Dorado array. The storage team has confirmed the LUN is created and mapped to the correct host group. The Fibre Channel zoning is also verified as correct. What is the most likely cause of this connectivity issue from the host's perspective?

    Answer and explanation

    Correct answer: B

    After storage-side mapping and network zoning are confirmed correct, the next logical place to troubleshoot is the host itself. On Linux systems, multipathing software (like DM-Multipath or Huawei's UltraPath) is required to manage paths to the storage and present a single device to the OS. If this service is not running or configured, the OS will not properly scan the bus and discover the LUNs, even if they are physically accessible.

  4. Question 4

    Multiple answers

    A financial institution is deploying a new Huawei OceanStor Pacific distributed storage cluster for archiving purposes. The primary goals are maximizing storage efficiency and ensuring data durability against multiple node failures. The data consists of large, immutable files. Which TWO of the following configurations should the architect choose to best meet these requirements? (Select TWO)

    Answer and explanation

    Correct answers: B, D

    Erasure coding provides high levels of data durability (tolerating multiple node failures) with significantly better storage efficiency compared to replication, making it ideal for large-scale archiving.

    For large, immutable archive files (like video or seismic data), deduplication is often ineffective as there are few common blocks. The computational overhead of enabling these features can degrade performance without providing significant space savings. Therefore, disabling them is a common best practice for such workloads.

  5. Question 5

    During routine maintenance, an administrator needs to perform a firmware upgrade on a controller in a high-availability OceanStor Dorado V6 cluster. To ensure services remain uninterrupted, this must be a non-disruptive upgrade (NDU). True or False: The administrator must first manually migrate all LUNs owned by the controller to be upgraded to its peer controller before starting the firmware update process.

    Answer and explanation

    Correct answer: B

    This statement is false. Modern storage arrays like the OceanStor Dorado V6 are designed with automated non-disruptive upgrade procedures. The system's upgrade process automatically handles the failover of services and LUN ownership from one controller to its peer before upgrading it. The administrator initiates the NDU, and the system manages the transparent failover and failback, eliminating the need for manual LUN migration.

  6. Question 6

    An e-commerce company uses a Huawei OceanStor Dorado array for its order processing database. The company experiences peak traffic between 9 AM and 5 PM, during which database performance is critical. A separate, less critical batch reporting job runs on the same array overnight. The administrator needs to ensure the reporting job does not consume excessive I/O resources that could impact the next day's database performance. Which feature allows the administrator to set specific IOPS and bandwidth limits for the LUNs used by the reporting application?

    Answer and explanation

    Correct answer: C

    SmartQoS (Quality of Service) is the feature designed to manage and control I/O performance for different applications. It allows an administrator to set upper limits on IOPS and bandwidth for specific LUNs, host groups, or other objects. This ensures that lower-priority applications, like the batch reporting job, do not negatively impact the performance of critical applications.

  7. Question 7

    A hospital is deploying a new Picture Archiving and Communication System (PACS) on a Huawei OceanStor storage system. The deployment plan requires creating a 50 TB file system. During the initial configuration on DeviceManager, which LUN feature must be enabled to allow the creation of a file system on that LUN?

    Answer and explanation

    Correct answer: D

    In Huawei OceanStor systems, when you provision storage for NAS (file services), you must first create a LUN that is specifically designated for this purpose. During the LUN creation process in DeviceManager, you must explicitly enable the 'File System' option for that LUN. This allocates the LUN to the NAS engine, making it available for file system creation.

  8. Question 8

    An administrator receives a critical alarm on an OceanStor Dorado array indicating a 'Disk Fault'. Upon inspection, the indicator light on the corresponding disk is steady amber. The administrator has a spare disk of the same model and capacity on hand. What is the correct sequence of actions to resolve this issue?

    flowchart TD A[Start] --> B{Verify Hot Spare}; B --> C[Remove Faulty Disk]; C --> D[Insert New Disk]; D --> E{Check Rebuild Status}; E --> F[End];
    Answer and explanation

    Correct answer: C

    The proper procedure for a hot-swappable disk failure is to first verify the system's status. This includes confirming the alarm, identifying the correct physical disk, and checking in DeviceManager to see if a hot spare disk has already been automatically activated and the data rebuild process has started. Once this is confirmed, the faulty disk (indicated by an amber light) can be safely removed and replaced. This ensures data protection is maintained throughout the process. Powering down is unnecessary for hot-swappable components.

  9. Question 9

    An administrator is responsible for a mixed-workload environment on a Huawei OceanStor Dorado V6. A high-priority online transaction processing (OLTP) application and a low-priority data analytics application share the same storage pool. The administrator needs to create a policy that guarantees a minimum of 4000 IOPS for the OLTP application at all times, while limiting the analytics application to a maximum of 1000 IOPS. Which SmartQoS policy type should be used for the OLTP application's LUNs?

    Answer and explanation

    Correct answer: B

    SmartQoS provides two main control policies. An 'Upper Limit' policy sets a maximum cap on resources (IOPS/bandwidth), which is suitable for the low-priority analytics application. A 'Lower Limit' policy guarantees a minimum level of resources, ensuring that even under heavy contention, the application will receive its required performance level. Therefore, to guarantee 4000 IOPS for the critical OLTP application, a Lower Limit policy must be applied.

  10. Question 10

    A consultant is designing a disaster recovery solution for a client with two data centers located 100 km apart. The client requires a near-zero Recovery Point Objective (RPO) for a critical file system hosted on a Huawei OceanStor array. Due to network latency over the 100 km distance, synchronous replication is not feasible. Which Huawei feature provides the lowest possible RPO in an asynchronous remote replication scenario?

    Answer and explanation

    Correct answer: C

    HyperMetro requires low latency and is not suitable for 100 km distances. For asynchronous HyperReplication, the RPO is determined by the synchronization period. To achieve the lowest possible RPO (near-zero), the administrator should configure the synchronization period to 'Real-time'. This setting ensures that data is replicated to the secondary site as soon as it is written to the primary, resulting in an RPO of just a few seconds, which is the best achievable over a high-latency link.

Register free to unlock 10 more sample questions

Lifetime One

Own this practice test forever.

$79.99
$75.99
one-time
  • Full access to 217 questions
  • Study, Timed & Flashcard Modes
  • All past and future versions i
  • Detailed Explanations
  • Study Tracking & Past Attempts
  • Brainy AI Assistant
  • Lifetime updates

Two

Any 2 exams per month.

$20.00/exam
$39.99
/month
  • 2 active exam slots
  • Study, Timed & Flashcard Modes
  • All past and future versions i
  • Detailed Explanations
  • Study Tracking & Past Attempts
  • 1,000 Brainy AI Credits
  • Cancel anytime

Premium Twelve

Any 12 exams over 3 months.

$15.00/exam
$179.99
/3 months
  • 4 active exam slots
  • Study, Timed & Flashcard Modes
  • All past and future versions i
  • Detailed Explanations
  • Study Tracking & Past Attempts
  • 15,000 Brainy AI Credits
  • Dedicated support
  • Friend seat included — full access

Trusted by professionals at

NvidiaSupabaseGitHubOpenAITursoClerkClaude AIAmazon