National Home Inspector Examination Free Sample Questions

12 free sample questions157 in the full practice test

Try simulator

NHIE Sample Questions

  1. Question 1

    Intermediate

    Property and Building Inspection/Site Review · Pool and Spa Access Barriers

    When inspecting a pedestrian access gate in an outdoor residential swimming pool barrier, the release mechanism for the latch is measured at 48 inches above finished grade. According to Consumer Product Safety Commission (CPSC) guidelines, what additional installation criteria must this latch meet?

    Answer and explanation

    Correct answer: B

    CPSC guidelines require latches mounted below 54 inches to be on the pool side at least 3 inches below the top, with openings limited to 1/2 inch within 18 inches to prevent reaching through.

  2. Question 2

    Intermediate

    Property and Building Inspection/Site Review · Pool and Spa Access Barriers

    During an exterior site inspection, an inspector observes a perimeter safety fence surrounding an inground swimming pool. While the section over concrete patio maintains a 3.5-inch vertical clearance to grade, a 20-foot section runs over a loose gravel bed with a 3.5-inch vertical clearance. How should the inspector evaluate this condition?

    Answer and explanation

    Correct answer: B

    While 4 inches is permissible over solid surfaces like concrete, CPSC guidelines require maximum clearance of 2 inches over non-solid surfaces like gravel or turf to prevent children crawling under.

  3. Question 3

    Beginner

    Property and Building Inspection/Site Review · Pool and Spa Access Barriers

    True or False: According to established residential pool barrier safety standards, an outdoor pedestrian access gate leading into a swimming pool enclosure is permitted to swing inward toward the pool, provided it is equipped with a self-closing and self-latching device.

    Answer and explanation

    Correct answer: A

    Pedestrian access gates must open outward away from the swimming pool area so that a small child leaning or pushing against the unlatched gate cannot force it open into the pool enclosure.

  4. Question 4

    Intermediate

    Property and Building Inspection/Site Review · Decks, Balconies, Stoops, Stairs, Steps, Porches and Associated Railings

    While inspecting an exterior wood deck attached to a single-family residence, an inspector notes that the 2x8 preservative-treated ledger board is secured with 1/2-inch lag screws directly through exterior stone veneer into the house rim joist. How should the inspector report this condition?

    Answer and explanation

    Correct answer: A

    IRC R507.9.1.1 strictly prohibits attaching deck ledgers to or over brick or stone veneer because veneer cannot support vertical deck loads and prevents positive structural clamping.

  5. Question 5

    AdvancedMultiple answers

    Property and Building Inspection/Site Review · Decks, Balconies, Stoops, Stairs, Steps, Porches and Associated Railings

    An inspector is evaluating guardrail and stair rail openings on an elevated exterior deck that stands 42 inches above the lawn. Which TWO of the following opening limitations comply with standard building safety provisions? (Select TWO)

    flowchart TD Walking["Deck Surface Guard (>30 in)"] --> G4["Max 4 in Sphere Opening"] StairRail["Stair Guard Infill"] --> G438["Max 4-3/8 in Sphere Opening"] StairTriangle["Bottom Rail & Tread/Riser"] --> G6["Max 6 in Sphere Opening"]
    Answer and explanation

    Correct answers: B, D

    IRC R312.1.3 mandates that intermediate rails or balusters on elevated guards cannot permit the passage of a sphere 4 inches (102 mm) in diameter.

    IRC R312.1.3 exception permits the triangular opening formed by the bottom rail, tread, and riser to be sized such that a 6-inch (152 mm) sphere cannot pass.

  6. Question 6

    Advanced

    Property and Building Inspection/Site Review · Decks, Balconies, Stoops, Stairs, Steps, Porches and Associated Railings

    An inspector is evaluating a second-story exterior wood deck that extends 12 feet out from the main building framing. The deck ledger is constructed of 2x10 preservative-treated lumber fastened to a 1-inch engineered rim board.

    Upon checking underneath the deck assembly, the inspector observes that the ledger is attached to the house using 3-inch spiral framing nails driven straight into the rim board, with no lag screws or through-bolts present. Additionally, there are no lateral hold-down tension hardware devices connecting the deck joists to the interior floor framing.

    Which of the following describes the primary structural hazard and correct reporting action for this deck assembly?

    Answer and explanation

    Correct answer: A

    Deck ledgers relying on nails in withdrawal fail catastrophically under load. IRC requires 1/2" bolts or lag screws and approved hold-down tension ties resisting lateral loads.

Register free for 6 more questions