NetApp NS0-093 Free Sample Questions

Create a free account to browse all 20 sample questions. The full practice test includes 178 questions. Use the simulator for timed and flashcard mode.

Try Simulator

NS0-093 Sample Questions

  1. Question 1

    Q1

    A field engineer is onsite to replace a failed hot-swappable Power Supply Unit (PSU) in a DS224C disk shelf that is part of a production AFF A250 system. The system must remain online during the procedure. After physically identifying the failed PSU by its amber fault LED, what is the correct next step to ensure a safe and non-disruptive replacement?

    Show answer & explanation

    Correct answer: B

    DS224C PSUs are fully redundant and hot-swappable. The correct procedure is to disconnect the power source from the failed unit, allow a brief period for it to power down completely, and then physically remove it. The redundant PSU will maintain power to the shelf. Placing the node in maintenance mode or taking the shelf offline is unnecessary and would cause an outage.

  2. Question 2

    Q2Multiple answers

    An administrator reports that a node in an AFF A400 cluster is unable to achieve cluster quorum after an unscheduled reboot. The other nodes in the cluster are healthy. The cluster show command output indicates the node is unhealthy and cannot communicate with its peers. Which TWO of the following are the most likely causes for this issue? (Select TWO).

    Show answer & explanation

    Correct answers: A, C

    A VLAN mismatch will prevent the node from communicating with other nodes over the cluster network, directly impacting its ability to join the quorum.

    A physical layer issue, such as a bad cable or SFP, is a primary cause for a single node to lose connectivity to the cluster interconnect, preventing it from participating in the quorum.

  3. Question 3

    Q3

    An administrator needs to collect detailed, real-time performance statistics for a specific LUN named 'SQL_LUN_01' that is reportedly experiencing high latency. The goal is to view the IOPS, throughput, and latency broken down by read, write, and other operations. Which command should the administrator use?

    Show answer & explanation

    Correct answer: D

    The qos statistics lun performance show command provides detailed, real-time performance data for a specific LUN, including IOPS, throughput, and latency. This is the correct tool for investigating performance at the individual LUN level. The other commands either provide less detail, operate at a different object level (like volume), or are legacy/incorrect syntax.

  4. Question 4

    Q4

    A financial services company runs a mixed workload on a single SVM hosted on a FAS8300 cluster running ONTAP 9.12.1. The IT department has received complaints about poor performance from users accessing SMB shares. Simultaneously, an automated NFS-based data ingestion process runs on the same SVM. A network administrator confirms there are no dropped packets on the switches connecting the storage to the clients.

    A junior storage administrator provides the following details:

    • The SVM has a single data LIF serving both SMB and NFS traffic.
    • The LIF is part of a single-port interface group using port e0c.
    • The NFS data ingestion workload is known to be very aggressive, often saturating the network link.
    • EMS logs show frequent messages indicating that the gNFS_Ex QoS policy, which has no throughput limit, is being used by the NFS clients.
    • SMB clients are not governed by any specific QoS policy.

    What is the most likely cause of the poor SMB performance?

    graph TD subgraph Corporate Network SMB_Clients[SMB Clients] --> Switch NFS_Client[NFS Data Ingestion Client] --> Switch end subgraph FAS8300 Cluster Switch --> e0c[Port e0c] e0c --> LACP[ifgrp a0a] LACP --> DataLIF[Data LIF: 192.168.10.100] DataLIF --> SVM end SVM -- Serves --> SMB_Share[SMB Share] SVM -- Serves --> NFS_Export[NFS Export] NFS_Client -- Aggressive Traffic --> NFS_Export SMB_Clients -- Slow Access --> SMB_Share

    Show answer & explanation

    Correct answer: B

    The core issue is resource contention on the shared network path (port e0c and the single data LIF). The aggressive NFS workload has no QoS limits, allowing it to consume all available network bandwidth. This creates a 'noisy neighbor' problem, where the SMB traffic cannot get sufficient bandwidth, resulting in high latency and poor performance. The solution would be to apply a QoS ceiling to the NFS workload or create separate network paths/LIFs for each protocol.

  5. Question 5

    Q5

    True or False: During an unplanned takeover in a NetApp HA pair, the surviving node replays the contents of its local NVLOG to commit writes that were in-flight on the failed node.

    Show answer & explanation

    Correct answer: B

    This statement is false. The surviving node replays the contents of the FAILED node's NVRAM, which is mirrored synchronously over the HA interconnect. The surviving node's own NVLOG contains its own in-flight writes, not the partner's. This process ensures that no acknowledged writes are lost during the failover.

  6. Question 6

    Q6

    A support engineer must configure an export-policy rule for an NFSv4.1 export that enforces Kerberos 5p (krb5p) security for all client access. The policy should deny access to any client not using krb5p. Which configuration is correct?

    Show answer & explanation

    Correct answer: C

    To enforce a specific Kerberos security level, the -rorule, -rwrule, and -superuser parameters must all be set to the desired level, in this case, krb5p. This ensures that read, write, and root access are all protected with encryption and integrity checking. Setting the protocol to nfs covers all versions, and the client match 0.0.0.0/0 applies the rule to all clients.

  7. Question 7

    Q7

    A support engineer has booted a node into maintenance mode to troubleshoot a boot failure. To verify the contents of the boot device, the engineer needs to list the directories at the root of the file system. Which command should be used?

    ls /________

    Show answer & explanation

    Correct answer: B

    In maintenance mode, the boot device's root file system is mounted under /mnt. Therefore, to see directories like /etc, /dev, etc., on the boot media, the engineer must list the contents of /mnt.

  8. Question 8

    Q8

    During routine maintenance on a FAS8700 controller, an amber fault light illuminates on the NVMEM/NVRAM battery. The controller is part of an active HA pair and must not be taken offline. What is the correct high-level procedure to replace the battery non-disruptively?

    Show answer & explanation

    Correct answer: A

    Even though some components are hot-swappable, the NVMEM/NVRAM battery is not. It is a critical component for protecting in-flight data. The correct non-disruptive procedure in an HA pair is to perform a takeover, which moves all services to the partner node. Then, the affected controller can be safely halted and powered down for the battery replacement. Once the hardware service is complete, the node is booted, and a giveback operation returns its services.

  9. Question 9

    Q9Multiple answers

    A support engineer is analyzing an AutoSupport bundle to diagnose the root cause of a system panic that generated a kernel core dump. The panic string references a memory parity error. Which TWO sections of the AutoSupport bundle are most critical for this investigation? (Select TWO).

    Show answer & explanation

    Correct answers: A, C

    The MESSAGES.GZ file contains the system log files, which include the panic message, stack trace, and events leading up to the panic. This is essential for understanding the context of the failure.

    The SYSCORE file is the compressed core dump itself. A deep analysis of this file using debugging tools is required to determine the exact instruction and memory address that caused the parity error and subsequent panic.

  10. Question 10

    Q10

    A disk in a 12-drive RAID-TEC aggregate fails and is replaced. During the subsequent RAID reconstruction process, a second disk within the same RAID group also fails. What will be the resulting state of the aggregate?

    Show answer & explanation

    Correct answer: B

    RAID-TEC (Triple Erasure Coding) is designed to withstand up to three simultaneous disk failures within a RAID group. The failure of a second disk during reconstruction will put the aggregate into a degraded state, but it will remain online and accessible. The reconstruction process will continue using the parity information from the remaining disks.

Register free to unlock 10 more sample questions

Create a free account to continue with the rest of the NS0-093 sample set.

Lifetime One

Own this practice test forever.

$79.99
$75.99
one-time
  • Full access to 178 questions
  • Study, Timed & Flashcard Modes
  • All past and future versions i
  • Detailed Explanations
  • Study Tracking & Past Attempts
  • Brainy AI Assistant
  • Lifetime updates

Two

Any 2 exams per month.

$20.00/exam
$39.99
/month
  • 2 active exam slots
  • Study, Timed & Flashcard Modes
  • All past and future versions i
  • Detailed Explanations
  • Study Tracking & Past Attempts
  • 1,000 Brainy AI Credits
  • Cancel anytime

Premium Twelve

Any 12 exams over 3 months.

$15.00/exam
$179.99
/3 months
  • 4 active exam slots
  • Study, Timed & Flashcard Modes
  • All past and future versions i
  • Detailed Explanations
  • Study Tracking & Past Attempts
  • 15,000 Brainy AI Credits
  • Dedicated support
  • Friend seat included — full access

Trusted by professionals at

NvidiaSupabaseGitHubOpenAITursoClerkClaude AIAmazon