Cisco and NetApp Flexpod Design Free Sample Questions

Description

Covers FlexPod component selection based on customer workloads, sizing solutions and support options, Cisco networking components and configurations, and management tools.

20 free sample questions203 in the full practice test Other version: NS0-177(150)

Try simulator

NS0-175 Sample Questions

  1. Question 1

    Advanced

    FlexPod Design · Select FlexPod components based upon customer workloads

    A financial services client is designing a FlexPod Datacenter solution to support a high-frequency trading application. The primary requirements are sub-millisecond storage latency and deterministic network performance. The design uses Cisco UCS X-Series compute, NetApp AFF A900 storage, and Cisco Nexus 9336C-FX2 switches. Which protocol and network configuration should be prioritized to meet these stringent performance requirements?

    Answer and explanation

    Correct answer: C

    For sub-millisecond latency and deterministic performance required by high-frequency trading, NVMe/RoCEv2 is the optimal choice. RoCEv2 (RDMA over Converged Ethernet) requires a lossless network, which is achieved by enabling Data Center Bridging (DCB) features like Priority-based Flow Control (PFC) on the Nexus switches. This configuration minimizes latency by bypassing much of the traditional network stack. iSCSI and NFS, while performant, cannot match the low latency of an RDMA-based protocol.

  2. Question 2

    Intermediate

    Security · Describe considerations in building a secure multitenancy design

    During a security audit of a multi-tenant FlexPod environment, it was discovered that a compromised VM in Tenant A's VLAN was able to send management traffic to the NetApp SVM management LIF of Tenant B. Both tenants are on the same NetApp AFF cluster but use separate VLANs and SVMs. Which configuration error is the most likely cause of this security vulnerability?

    Answer and explanation

    Correct answer: B

    The default firewall policy for a LIF allows traffic from all subnets, which is insecure for a multi-tenant environment. If the management LIFs for both tenants used this default, and there was any L3 path between the VLANs, cross-tenant management access would be possible. Best practice is to create custom firewall policies for each SVM's management LIF that only permit access from authorized management subnets for that specific tenant. While being in the same IPspace or having an open export policy are issues, they don't specifically explain the cross-tenant management access.

  3. Question 3

    Intermediate

    Networking · Describe FlexPod networking configurations

    An architect is designing a FlexPod solution for a distributed analytics workload that requires massive parallel processing across many compute nodes. The design must accommodate bursts of east-west traffic between nodes without creating bottlenecks. Which Cisco Nexus feature is most critical for providing a non-blocking, highly available network fabric between the UCS Fabric Interconnects and the core network?

    graph TD subgraph Core Network CORE1 & CORE2 end subgraph FlexPod Nexus Layer NEXUS1(Nexus 9K A) NEXUS2(Nexus 9K B) end subgraph FlexPod Compute Layer FI_A(UCS FI-A) FI_B(UCS FI-B) end CORE1 & CORE2 -- L3 Routing --> NEXUS1 & NEXUS2 NEXUS1 -- vPC Peer Link --- NEXUS2 NEXUS1 -- vPC Port-Channel --> FI_A NEXUS2 -- vPC Port-Channel --> FI_A NEXUS1 -- vPC Port-Channel --> FI_B NEXUS2 -- vPC Port-Channel --> FI_B
    Answer and explanation

    Correct answer: B

    Virtual Port Channel (vPC) is the key technology used in FlexPod to provide a loop-free, active-active Layer 2 topology. It allows downstream devices like the UCS Fabric Interconnects to form a single port-channel across two separate physical Nexus switches. This doubles the available bandwidth and provides seamless failover if one Nexus switch fails, which is critical for the high-availability and high-bandwidth east-west traffic patterns of distributed analytics.

  4. Question 4

    Intermediate

    Tools · Describe tools for managing FlexPod

    A customer wants to deploy a new FlexPod solution using Cisco Intersight Managed Mode (IMM) for the UCS B-Series servers. They also want to integrate their existing NetApp ONTAP cluster and VMware vCenter instance for unified monitoring within the Intersight dashboard. What component is required to facilitate this integration?

    Answer and explanation

    Correct answer: C

    Cisco Intersight Assist is a virtual appliance deployed on-premises that acts as a bridge between the cloud-based Intersight platform and on-premises endpoints like NetApp ONTAP and VMware vCenter. It enables Intersight to claim and monitor these third-party systems, providing a single pane of glass for the entire FlexPod stack, even when using Intersight Managed Mode for compute.

  5. Question 5

    Advanced

    Security · Describe access control methods for FlexPod solutions

    You are designing a FlexPod solution that will host a sensitive database requiring data-at-rest encryption. The corporate security policy mandates that encryption keys must be managed by a centralized, FIPS 140-2 compliant hardware security module (HSM) appliance. Which NetApp ONTAP feature and protocol must be configured to meet this requirement?

    Answer and explanation

    Correct answer: C

    The requirement for a centralized, FIPS 140-2 compliant HSM dictates the use of an external key manager. NetApp ONTAP integrates with external key managers using the Key Management Interoperability Protocol (KMIP). NetApp Volume Encryption (NVE) is the feature that provides software-based data-at-rest encryption and can be configured to retrieve its keys from the external KMIP server, thus satisfying the security policy.

  6. Question 6

    IntermediateMultiple answers

    Networking · Describe FlexPod networking configurations

    When designing a FlexPod solution with end-to-end jumbo frame support (MTU 9216) for iSCSI traffic, which THREE components must have their MTU size explicitly configured? (Choose THREE.)

    Answer and explanation

    Correct answers: A, B, D

  7. Question 7

    Intermediate

    FlexPod Design · Size a solution based on customer requirements in accordance with FlexPod best practices

    A hospital is deploying a FlexPod Datacenter solution for its new Electronic Health Record (EHR) system. Key requirements include continuous availability and zero data loss in the event of a site failure. The two data centers are 50 km apart with a dedicated 10Gbps dark fiber link. Which NetApp technology should be the core of the storage design to meet these requirements?

    Answer and explanation

    Correct answer: B

    NetApp MetroCluster IP is designed specifically for this use case. It provides synchronous replication between two sites up to 700km apart, delivering continuous availability and zero data loss (RPO=0). It creates an active-active storage cluster that can transparently fail over in the event of a site disaster, making it ideal for critical applications like an EHR system. SnapMirror Synchronous is a volume-level solution, whereas MetroCluster provides a complete site-level disaster recovery solution.

  8. Question 8

    Beginner

    Networking · Describe Cisco networking components used within FlexPod designs

    True or False: In a standard FlexPod Datacenter design, the Cisco UCS Fabric Interconnects must be directly connected to the NetApp storage controllers for iSCSI traffic.

    Answer and explanation

    Correct answer: B

    In a standard FlexPod Datacenter design, both the Cisco UCS Fabric Interconnects and the NetApp storage controllers connect to the upstream Cisco Nexus switches. The Nexus switches provide the Layer 2 fabric for all data traffic, including iSCSI. There is no direct connection between the FIs and the storage controllers.

  9. Question 9

    Beginner

    Tools · Describe resources for determining supported FlexPod components

    A consultant is performing a health check on a FlexPod environment and finds that NetApp ONTAP firmware is two years out of date. Before recommending an upgrade, the consultant needs to verify that the proposed new ONTAP version is compatible with the installed versions of Cisco UCS firmware, Nexus NX-OS, and VMware ESXi. Which tool is the definitive resource for this verification?

    Answer and explanation

    Correct answer: D

    The NetApp Interoperability Matrix Tool (IMT) is the authoritative source for verifying compatibility between all components in a FlexPod solution. It allows users to select specific versions of ONTAP, UCS firmware, NX-OS, ESXi, and other software to ensure they form a supported and validated configuration. While other tools provide health and compatibility information, the IMT is the primary tool for this specific cross-vendor validation task.

  10. Question 10

    Advanced

    Security · Describe considerations in building a secure multitenancy design

    Case Study:

    A regional bank is consolidating its data centers into a new FlexPod Datacenter platform. The bank has two primary business units, Retail Banking and Investment Banking, that must be securely isolated from each other. The Retail Banking unit runs a large number of general-purpose virtual machines with predictable performance needs. The Investment Banking unit runs a high-performance analytics platform that is latency-sensitive and can consume large amounts of storage IOPS during market hours.

    The CISO has mandated strict logical separation at all layers (compute, network, storage) and the ability to enforce resource limits to prevent the Investment Banking workload from impacting the Retail Banking services. The solution will use Cisco UCS B-Series servers, Nexus 93180 switches, and a single NetApp AFF A400 cluster.

    Which combination of technologies provides the most comprehensive solution to meet the bank's security and performance isolation requirements?

    Answer and explanation

    Correct answer: C

    This option provides a complete, multi-layered isolation strategy. Separate SVMs with distinct IPspaces create strong logical separation at the storage layer, including separate administrative domains and network interfaces. Separate VLANs isolate network traffic. Finally, applying NetApp QoS policies (with an IOPS ceiling) to the Investment Banking volumes directly addresses the requirement to prevent that workload from impacting the Retail Banking services, fulfilling all aspects of the case study.

Register free for 10 more questions

Or unlock all 203 NS0-175 questions with explanations, timed mode and flashcards.