Question 1
A deployment engineer is finalizing the network plan for a new 8-node VxRail P-Series cluster that will leverage vSAN Express Storage Architecture (ESA). The customer's top-of-rack switches are Dell S5248F-ON models. To maximize performance and ensure redundancy, which physical network cabling and VDS uplink configuration represents the best practice?
Answer and explanation
Correct answer: D
vSAN ESA requires a minimum of 10GbE networking, but 25GbE is strongly recommended for optimal performance. The best practice for redundancy and performance is to use two 25GbE ports connected to separate physical switches in an active/active configuration on the vSphere Distributed Switch (VDS). This avoids a single point of failure at the switch level and utilizes all available bandwidth. LACP provides link redundancy but not switch redundancy. Using 10GbE is suboptimal for ESA, and separating traffic across different active/standby pairs is less efficient than an active/active model.