Cisco FlexPod Implementation and Administration Free Sample Questions

Create a free account to browse all 20 sample questions. The full practice test includes 235 questions. Use the simulator for timed and flashcard mode.

Try Simulator

500-174 Sample Questions

  1. Question 1

    Q1

    A financial services client is deploying a new FlexPod Datacenter with NetApp AFF A250, Cisco UCS B200 M6 blades, and Nexus 93180YC-FX switches. To comply with strict data sovereignty regulations, they must ensure that all NFSv4.1 traffic for their European user base is handled exclusively by a dedicated SVM and its associated LIFs. Which ONTAP feature is the most direct and effective way to enforce this traffic segmentation at the network level?

    Show answer & explanation

    Correct answer: A

    IPspaces in ONTAP provide complete network stack separation, including routing tables, port sets, and broadcast domains. By placing the European SVM and its LIFs into a dedicated IPspace, you create a logically isolated network environment, ensuring that its traffic cannot mix with other SVMs in different IPspaces. This is the most robust method for enforcing strict network segmentation for compliance.

  2. Question 2

    Q2Multiple answers

    During the initial setup of a Cisco UCS 6454 Fabric Interconnect pair, an administrator must decide between End-Host Mode and Switch Mode for Ethernet switching. The upstream network consists of a pair of Nexus 9000 switches configured for vPC. Which two statements accurately describe the implications of choosing End-Host Mode in this scenario? (Select TWO)

    Show answer & explanation

    Correct answers: A, B

    In End-Host Mode, the UCS Fabric Interconnects behave like a host with many network adapters to the upstream network. They do not participate in the Spanning Tree Protocol (STP), which prevents potential STP loops and simplifies the network topology.

    A key characteristic of End-Host Mode is that it pins server MAC addresses to specific uplink ports. To achieve active-active uplinks to a vPC pair of Nexus switches, each Fabric Interconnect must have a port-channel to each Nexus switch, and these are bundled into a vPC. This allows for seamless failover and load distribution.

  3. Question 3

    Q3

    A FlexPod administrator is provisioning a new UCS Service Profile for a database server that requires SAN boot. The storage team has provisioned a LUN on the NetApp AFF array. When configuring the boot policy, the administrator needs to specify the World Wide Port Name (WWPN) of the target. Where is the correct WWPN for the FC SAN LIF found?

    Show answer & explanation

    Correct answer: A

    The network interface show -vserver -lif -fields wwpn command in the ONTAP CLI will display the WWPN of the Fibre Channel Logical Interface (LIF). This is the correct target WWPN that needs to be used in the UCS boot policy and for zoning on the FC switches.

  4. Question 4

    Q4

    True or False: When performing a non-disruptive software upgrade (ISSU) on a pair of Nexus 9000 series switches configured with vPC, the operational role of the vPC primary switch is automatically transferred to the secondary switch before the upgrade process begins on the primary.

    Show answer & explanation

    Correct answer: A

    This statement is true. A key part of the ISSU process in a vPC environment is to ensure service continuity. Before upgrading the vPC primary switch, the system gracefully transfers the primary role to the vPC secondary peer. This ensures that the secondary switch continues to forward traffic and handle control plane functions while the original primary is upgraded. After the first switch reloads and comes back online, the roles may or may not be switched back depending on the configuration.

  5. Question 5

    Q5

    A hospital is expanding its FlexPod infrastructure to support a new Electronic Health Record (EHR) system. The new UCS C-Series servers will connect via iSCSI to a NetApp AFF C190. The network administrator is creating a dedicated VLAN and subnet for iSCSI traffic. According to Cisco and NetApp best practices for iSCSI performance and reliability, which network feature should be enabled on the Nexus switch ports connected to the servers and storage?

    Show answer & explanation

    Correct answer: B

    Enabling Jumbo Frames (setting the Maximum Transmission Unit, or MTU, to 9000 or higher, typically 9216 on Nexus) is a critical best practice for iSCSI. It allows larger payloads per packet, which reduces the number of packets and CPU cycles required on both the initiator (server) and target (storage) to transfer the same amount of data. This significantly improves throughput and efficiency for block storage traffic.

  6. Question 6

    Q6

    An administrator is setting up a new NetApp aggregate on a FAS8300 system as part of a FlexPod deployment. The aggregate will consist of 24 SAS disks. To provide the highest level of data protection against multiple simultaneous disk failures, the administrator should use the ___________ RAID type.

    Show answer & explanation

    Correct answer: C

    RAID-TEC (Triple Erasure Coding) is NetApp's implementation of triple-parity RAID. It can withstand up to three simultaneous disk failures within a RAID group, providing the highest level of data protection available in ONTAP. It is recommended for large capacity drives where rebuild times are longer.

  7. Question 7

    Q7

    A media company uses FlexPod to host its video rendering farm. They need to ensure that rendering traffic has guaranteed bandwidth while management and vMotion traffic receive best-effort service. Which UCS Manager component should be configured to define these traffic priorities?

    Show answer & explanation

    Correct answer: B

    QoS System Classes in UCS Manager are used to define policies for different types of traffic (e.g., Fibre Channel, iSCSI, and user-defined classes). By creating a QoS policy and assigning it to a vNIC used for rendering traffic, an administrator can set a specific weight or priority, guaranteeing it a percentage of the available bandwidth, while other classes like management can be left at the default best-effort level.

  8. Question 8

    Q8

    After a maintenance window, an administrator discovers that several ESXi hosts in a FlexPod environment can no longer see their iSCSI datastores. The administrator confirms that the iSCSI LIFs are online on the NetApp array and that basic network connectivity (ping) exists between the ESXi hosts' iSCSI vmkernels and the NetApp LIFs. What is the most likely cause of this issue?

    Show answer & explanation

    Correct answer: C

    This is the most common cause for this symptom. iSCSI connectivity relies on the storage array recognizing the host's initiator IQN and having it mapped to the LUNs. If the IQNs were accidentally removed from the igroup that is mapped to the LUNs, the NetApp array would no longer present the LUNs to those hosts, even if network connectivity is perfect. This can happen during maintenance if configurations are reverted or incorrectly modified.

  9. Question 9

    Q9

    A new FlexPod solution is being deployed with Cisco UCS C240 M6 servers that will be managed by UCS Manager. How are these rack-mount servers physically connected to the Fabric Interconnects to enable UCS Manager control?

    Show answer & explanation

    Correct answer: C

    To integrate a C-Series rack server into a UCS domain managed by UCS Manager, it must be equipped with a Cisco Virtual Interface Card (VIC). The VIC's ports are then directly cabled to the Fabric Interconnects. This connection carries both data and management traffic, allowing UCS Manager to discover, inventory, and fully manage the server using Service Profiles.

  10. Question 10

    Q10

    A consultant is designing a FlexPod solution for a client who requires both high-performance block storage for a database and scalable file storage for user home directories. Which combination of NetApp storage components is most appropriate for this design?

    Show answer & explanation

    Correct answer: B

    This is the ideal combination. A NetApp All-Flash FAS (AFF) system provides the extremely low latency and high IOPS required for demanding database workloads. A hybrid NetApp FAS system (with a mix of SSD and HDD) offers a cost-effective and scalable solution for file storage like home directories, where performance is less critical than capacity and cost per GB. Both run ONTAP, simplifying management.

Register free to unlock 10 more sample questions

Create a free account to continue with the rest of the 500-174 sample set.

Lifetime One

Own this practice test forever.

$79.99
$75.99
one-time
  • Full access to 235 questions
  • Study, Timed & Flashcard Modes
  • All past and future versions i
  • Detailed Explanations
  • Study Tracking & Past Attempts
  • Brainy AI Assistant
  • Lifetime updates

Two

Any 2 exams per month.

$20.00/exam
$39.99
/month
  • 2 active exam slots
  • Study, Timed & Flashcard Modes
  • All past and future versions i
  • Detailed Explanations
  • Study Tracking & Past Attempts
  • 1,000 Brainy AI Credits
  • Cancel anytime

Premium Twelve

Any 12 exams over 3 months.

$15.00/exam
$179.99
/3 months
  • 4 active exam slots
  • Study, Timed & Flashcard Modes
  • All past and future versions i
  • Detailed Explanations
  • Study Tracking & Past Attempts
  • 15,000 Brainy AI Credits
  • Dedicated support
  • Friend seat included — full access

Trusted by professionals at

NvidiaSupabaseGitHubOpenAITursoClerkClaude AIAmazon