Why Study with PlanetCert?
The Latest Questions
Practice questions and exam topics aligned with the current exam objectives.
Detailed Explanations
Go beyond the answer. Master the material with comprehensive learning and professional explanations for every concept.

AI-Powered Insights
Personalized preparation guidance that adapts to your performance and identifies weak spots automatically.
Exam Information
Official specifications published by Cisco
Exam Format
Registration
Validity
Skills this practice test covers
- Set up a Fabric Interconnect pair in end-host or switched mode and justify the choice.
- Build UCS service profiles from templates, drawing on UCS pools such as MAC and IP pools.
- Create ONTAP aggregates, storage virtual machines and SAN or NAS LIFs.
- Join the Nexus switches with a vPC, then add the VLANs and port channels that FlexPod traffic needs.
- Map a LUN to a host for SAN boot and zone the correct WWPN.
- Install and upgrade ONTAP, UCS, Nexus and hypervisor software in a FlexPod.
Explore related topics
500-174 exam content
5 domains · 37 topics · 235 questions
Information Gathering for FlexPod Solutions10%22 questions
This domain covers what a FlexPod is made of. Candidates describe its network, compute and storage components and the Cisco UCS components, from the Fabric Interconnects to the servers.
Skills tested
- List what each FlexPod layer contributes: network, compute and storage.
- Explain what the Fabric Interconnects do in a Cisco UCS domain.
- Describe the UCS server types and where each one fits.
Questions by topic
- Describe the Cisco UCS components10
- Describe the main FlexPod components5
- Describe the storage components used in FlexPod2
- Describe the Cisco UCS servers used in FlexPod3
- Storage virtual machine1
- Describe network switches supported in FlexPod1
FlexPod Design10%22 questions
Here the parts list gets decided. Storage can be NetApp E-Series or FAS/AFF, switching comes from the Nexus 3000 or Nexus 9000 families and their operating systems, and compute from C-Series rack servers or B-Series blades in a UCS chassis.
Skills tested
- Decide when a workload calls for E-Series storage and when for FAS/AFF.
- Tell which Nexus 3000 and 9000 models and operating systems a FlexPod supports.
- Weigh blade servers in a B-Series chassis against C-Series rack servers.
Questions by topic
- Describe the storage components used in FlexPod7
- Describe the Cisco UCS servers used in FlexPod5
- Describe network switches supported in FlexPod1
- Describe how to initialize the Fabric Interconnect3
- Describe the main FlexPod components3
- vPC2
- Licenses1
FlexPod Configuration34%95 questions
Building the FlexPod is the heaviest domain. It runs from the first install of each layer through Fabric Interconnect setup, UCS pools, networks and service profiles, and SAN boot, to ONTAP storage and Nexus switch configuration.
Skills tested
- Bring up a new pair of Fabric Interconnects and describe how the Cisco UCS is wired inside.
- Configure UCS QoS, port channels and the pools that service profiles draw from.
- Create a service profile template and configure SAN boot with a LUN mapped to the host.
- Build an ONTAP aggregate and storage virtual machine, and explain why RAID-TEC and broadcast domains matter.
- Install Nexus licenses, then set up VLANs, port channels and a vPC pair.
Official topics
- Demonstrate knowledge of how to install and configure the FlexPod components
- Describe how to initialize the Fabric Interconnect
- Demonstrate knowledge of how to configure networks in a UCS solution
- Describe when to configure SAN boot in a FlexPod solution
- Demonstrate knowledge of how to configure a service profile
- Demonstrate knowledge of how to configure storage in a FlexPod solution
- Demonstrate knowledge of how to configure Cisco Nexus switches
FlexPod Administration26%50 questions
This domain is the work after go-live. Candidates follow FlexPod best practices, such as switching UCS call home and NetApp AutoSupport on or off, use the UCS and storage management applications, and install and upgrade ONTAP, UCS, Nexus and hypervisor software.
Skills tested
- Switch the UCS call home feature and NetApp AutoSupport on or off, and say when each helps.
- Follow the UCS Manager process that reserves a block of KVM IP addresses.
- Match each management task to its tool, whether it concerns UCS or the storage system.
- Upgrade ONTAP, UCS, Nexus and hypervisor software with as little disruption as possible.
Questions by topic
- Demonstrate knowledge of how to install and upgrade the FlexPod solution14
- Process for adding a block of IP addresses for KVM Access to UCS using UCS Manager5
- Ability to enable/disable NetApp AutoSupport5
- Describe FlexPod management applications6
- Ability to enable/disable the UCS call home feature3
- Storage system management7
- Other tools2
- UCS Management5
- Configure UCS service profile/template1
- Configuration of UCS pools to be created2
FlexPod Troubleshooting20%46 questions
When a FlexPod misbehaves, this domain asks for the cause. Candidates work through boot problems, network problems, FC zoning with the correct WWPN for the SAN LIF, and iSCSI IQN targets.
Skills tested
- Find why a server fails to boot from SAN.
- Zone the correct WWPN to an FC SAN LIF.
- Check iSCSI IQN targets and initiator groups when a host cannot see its LUN.
- Trace a network problem from the Nexus switches to the Fabric Interconnects.
Questions by topic
- The correct WWPN to zone FC SAN LIF5
- Demonstrate how to perform basic FlexPod troubleshooting7
- Network problems15
- Boot problems10
- iSCSI IQN targets6
- Storage system management2
- Describe when to configure SAN boot in a FlexPod solution1
Requirements
- No formal prerequisites: anyone can book the exam.
- Recommended: between six months and a year of hands-on FlexPod field work.
- Recommended: a basic grasp of data center architecture and of hypervisors from VMware, Red Hat or Microsoft.
- Recommended: working knowledge of Cisco UCS servers and NetApp storage.
About the 500-174 exam
FlexPod Implementation and Administration (500-174) tests whether an engineer can put a FlexPod into service and keep it healthy. A FlexPod combines Cisco UCS compute, Cisco Nexus networking and NetApp storage, and Cisco's topics place it in a realistic network with more than one hypervisor. The exam also asks how the FlexPod solution fits the wider data center architecture. Passing it earns the Cisco and NetApp FlexPod Implementation and Administration Specialist certification.
FlexPod Configuration carries the most weight, so the PlanetCert practice test spends the most questions on Fabric Interconnects, service profiles, SAN boot, ONTAP storage and Nexus switching. The explanations follow each fault across the stack, for example a server that cannot boot because its WWPN is zoned to the wrong LIF. Study Mode suits the troubleshooting domain, where boot and network problems need a careful read. Brainy AI Assistant can explain how SAN and NAS LIFs differ or how RAID-TEC protects an aggregate.
How to earn the certification
- Earns
- Cisco and NetApp FlexPod Implementation and Administration SpecialistSpecialist
The specialist certification stays valid for three years.
- Before
- 200-301 Cisco Certified Network Associate (CCNA)
Optional. CCNA-level networking helps with the Nexus and UCS network tasks.
- 200-301 Cisco Certified Network Associate (CCNA)
- After
- 350-601 Implementing and Operating Cisco Data Center Core Technologies (DCCOR)
Cisco's data center core exam and the first step toward CCNP Data Center.
- 300-615 Troubleshooting Cisco Data Center Infrastructure (DCIT)
A CCNP Data Center concentration exam on troubleshooting data center infrastructure.
- 350-601 Implementing and Operating Cisco Data Center Core Technologies (DCCOR)
How to prepare for 500-174
- 1
Sort the topics by stack layer
Place each exam topic under network, compute, storage or hypervisor. Many FlexPod questions cross two layers, such as SAN boot, which needs UCS, the fabric and ONTAP to agree.
- 2
Practise in UCS and ONTAP simulators
When no FlexPod lab is available, use Cisco UCS and NetApp ONTAP simulators. Initialize the Fabric Interconnects, build pools and service profiles, then create aggregates and storage virtual machines.
- 3
Walk SAN boot from end to end
Configuration carries the most weight. Follow one SAN boot setup from the boot policy through zoning and LUN mapping to a running host, then repeat it over iSCSI.
- 4
Rehearse the administration routines
Turn call home and AutoSupport on and off, add KVM addresses in UCS Manager, and write an upgrade order for the storage, compute, network and hypervisor software.
- 5
Close with the FlexPod practice test
Run the 500-174 practice test in Study Mode one domain at a time, then in Timed Mode. Ask Brainy AI Assistant about any boot or zoning question that went wrong.
Start a timed 500-174run
Cisco recommends the Implementing and Administering the FlexPod Solutions (FPIMPADM) course for this exam.
Who 500-174 is for
- Field engineers who install FlexPod systems at customer sites.
- Engineers at Cisco and NetApp channel partners who deliver FlexPod projects.
- Data center administrators who keep a FlexPod running after go-live.
- Professional services consultants who plan upgrades and fix faults in existing FlexPods.
Typical job titles: Field engineer · Data center engineer · Systems engineer · Storage engineer · Converged infrastructure administrator · Professional services consultant
500-174 glossary
19 terms from the exam objectives and the vendor's official material, each defined in a sentence.
- Broadcast domain
- An ONTAP grouping of ports that share one Layer 2 network; a LIF can only fail over to ports in the same group.
- E-Series
- NetApp's SAN-only storage systems, an alternative to the FAS/AFF line for some FlexPod designs.
- End-host mode
- The default Fabric Interconnect mode: toward the upstream LAN it behaves like a group of hosts, so spanning tree is not needed.
- Fabric Interconnects
- The pair of switches that connect every UCS server to the LAN and SAN and run UCS Manager.
- FAS/AFF
- NetApp's ONTAP systems: FAS models use hard disks or hybrid storage, and AFF models are all-flash.
- iSCSI IQN
- iSCSI qualified name: the identifier, written in a set format, that names each iSCSI initiator and target.
- KVM
- Keyboard, video and mouse access to a UCS server's console over the network.
- LIF
- A logical interface in ONTAP: the address through which hosts reach data, with SAN and NAS LIFs behaving differently on failover.
- LUN
- Logical unit number: a slice of SAN storage that a host sees and uses as if it were a local disk.
- NetApp AutoSupport
- NetApp's automatic reporting of a storage system's health and settings to NetApp, used for monitoring and support cases.
- RAID-TEC
- NetApp's triple-parity RAID, which protects data even if three disks in a RAID group fail.
- SAN boot
- Loading a server's operating system over the SAN from a boot LUN, so the server needs no local disk.
- Service profile
- A logical server in UCS: the MAC addresses, WWPNs, boot order and policies that any suitable blade or rack server can take on.
- Storage aggregate
- In ONTAP, a pool of disks protected by RAID, from which volumes take their space.
- Storage virtual machine
- A virtual storage server in ONTAP that owns volumes and LIFs and serves data to hosts.
- UCS call home
- A UCS feature that sends fault alerts by email to the support team or to Cisco.
- UCS Manager
- The software built into the Fabric Interconnects for configuring and watching every server in its UCS domain.
- vPC
- Virtual port channel: two Nexus switches act as one end of a port channel, so a device can spread its links across both.
- WWPN
- World wide port name: the fixed identity of one Fibre Channel port, which zoning and LUN masking refer to.
Related practice tests
- 300-535Automating and Programming Cisco Service Provider Solutions (SPAUTO)
- 200-901CCNA Automation (DevNet Associate)
- 200-201CCNA Cybersecurity (CyberOps Associate)
- 200-301Cisco Certified Network Associate (CCNA)
- 300-420Designing Cisco Enterprise Networks (ENSLD)