Why Study with PlanetCert?
The Latest Questions
Practice questions and exam topics aligned with the current exam objectives.
Detailed Explanations
Go beyond the answer. Master the material with comprehensive learning and professional explanations for every concept.

AI-Powered Insights
Personalized preparation guidance that adapts to your performance and identifies weak spots automatically.
Exam Information
Official specifications published by Cisco
Exam Format
Registration
Validity
Skills this practice test covers
- Select UCS, Nexus and NetApp parts that fit a customer's workloads, scale and business continuity needs.
- Size a FlexPod design against its connectivity and performance requirements.
- Configure UCS templates and service profiles for hypervisor and database hosts.
- Choose FAS, AFF or E-Series storage and a SAN or NAS protocol for each workload.
- Keep tenants apart with IP Spaces, VLANs, VSANs and SVMs.
- Check support in the IMT and HCL, then troubleshoot compute, network and storage faults.
Explore related topics
500-173 exam content
6 domains · 27 topics · 197 of 207 questions sorted by domain
FlexPod Design25%46 questions
This domain turns customer workloads into a design. Candidates weigh scale, FlexPod rules, connectivity, performance, business outcomes and business continuity, size the solution by FlexPod best practices, and know the support options.
Skills tested
- Match FlexPod components to the workloads a customer runs.
- Size a design for scale, connectivity and performance in line with FlexPod best practices.
- Explain cooperative support, partner support and solution support for FlexPod.
Questions by topic
- Business Continuity7
- Describe the support options for FlexPod6
- Business outcomes desired4
- Best practices3
- Performance requirements5
- Connectivity requirements4
- FlexPod rules4
- Scale4
- Describe FlexPod components based upon customer workloads5
- Describe how to size a solution based on customer requirements4
Compute20%41 questions
This domain is the Cisco UCS side. Candidates describe B-Series and C-Series servers, Fabric Interconnects, IOMs and VICs, and they configure the logical parts of a UCS server, such as templates and profiles.
Skills tested
- Choose between B-Series blades and C-Series rack servers for a design.
- Explain how Fabric Interconnects, IOMs and VICs connect servers to the LAN and SAN.
- Build service profiles from templates for hypervisor and database hosts.
Questions by topic
- Describe the Cisco UCS components used within FlexPod designs21
- Demonstrate knowledge of how to configure the logical components used in a UCS server19
- Demonstrate knowledge of troubleshooting methodologies for FlexPod solutions1
Storage18%37 questions
This domain is the NetApp side. Candidates describe FAS, AFF and E-Series systems and clustering, weigh SAN and NAS protocols with the FC hardware they need, and plan data protection, backup and restore.
Skills tested
- Pick FAS, AFF or E-Series storage for a stated workload.
- Choose between SAN and NAS protocols, and plan FC hardware and VSANs.
- Plan data protection, backup, restore and data security for the design.
Questions by topic
- Describe NetApp storage components used within FlexPod designs15
- Describe storage protocol considerations in FlexPod designs7
- Demonstrate knowledge of the features required for data protection or backup for FlexPod design9
- Data security2
- Data protection4
Networking18%29 questions
This domain covers the Cisco switches that join compute and storage. Candidates describe ACI, Nexus and MDS components, and they configure VLANs and virtual port channels (vPCs) for a FlexPod.
Skills tested
- Place Nexus switches, MDS switches or an ACI fabric in a FlexPod design.
- Configure VLANs and vPCs so that one switch failure does not cut a path.
Questions by topic
- Demonstrate knowledge of FlexPod networking configurations14
- Describe Cisco networking components used within FlexPod designs15
Security9%20 questions
This domain covers who may manage the system and how tenants stay apart. Candidates describe access control through LDAP, RADIUS and AD, and design secure multitenancy with IP Spaces, VLANs, VSANs and SVMs.
Skills tested
- Set up administrator access through LDAP, RADIUS or Active Directory.
- Keep tenants apart in the network, SAN and storage layers.
Questions by topic
- Describe the considerations in building a secure multitenancy design10
- Describe access control methods for FlexPod solutions8
- Data security2
Tools10%24 questions
This domain covers the resources that confirm a design is supported and the tools that run it. Candidates use TRs, the IMT and the HCL, manage FlexPod with tools such as UCS Manager and UCS Director, and troubleshoot by layer.
Skills tested
- Confirm that a design is supported with TRs, the IMT and the HCL.
- Use management tools to run and automate a FlexPod.
- Troubleshoot a fault by layer: compute, networking, then storage.
Questions by topic
- Describe resources for determining supported FlexPod components7
- Demonstrate knowledge of using tools for managing FlexPod6
- Demonstrate knowledge of troubleshooting methodologies for FlexPod solutions10
- Describe how to size a solution based on customer requirements1
Requirements
- No formal prerequisites: anyone can book the exam.
- Recommended: six to twelve months of field experience with FlexPod solutions.
- Recommended: working knowledge of Cisco UCS, NetApp ONTAP and Cisco networking.
- Recommended: an understanding of converged infrastructure and of virtualization platforms such as VMware vSphere.
About the 500-173 exam
FlexPod design is the whole subject of 500-173, a specialist exam for engineers who plan converged data centers built from Cisco UCS servers, Cisco switches and NetApp storage. Cisco describes it as a test of judging a solution's performance needs and picking the right hardware for a set of requirements. The domains move from design and sizing through compute, storage, networking and security to the tools for support checks and troubleshooting. Passing earns the Cisco and NetApp FlexPod Design Specialist certification.
FlexPod Design gets the most questions in the PlanetCert practice test, with Compute close behind, where UCS hardware and its logical setup lead. The explanations tie each answer to a customer requirement in the question, such as a growth target or a need for block storage. Study Mode suits the storage and networking questions, where FAS, AFF and E-Series, or VSANs and VLANs, are easy to confuse. Brainy AI Assistant can explain how an SVM keeps one tenant's data apart, or where to check that a firmware version is supported.
How to earn the certification
- Earns
- Cisco and NetApp FlexPod Design SpecialistSpecialist
How to prepare for 500-173
- 1
Read a FlexPod Datacenter design guide
A Cisco Validated Design for FlexPod Datacenter shows how the UCS, Nexus and NetApp parts fit together and which rules the design follows. Read one end to end before the domain topics.
- 2
Size one design for a real workload
Take a sample workload, such as a virtual desktop farm or a database cluster, and size compute, storage and links for it. Note how scale, performance and business continuity change each choice.
- 3
Draw the path from blade to disk
Sketch how a blade reaches its storage: blade, VIC, IOM, Fabric Interconnect, Nexus or MDS switch, then the NetApp controller. Mark where VLANs, VSANs and service profiles apply.
- 4
Look up support in the IMT and HCL
Check one server, firmware and storage combination in the NetApp IMT and the Cisco UCS HCL. The Tools domain expects candidates to know which resource answers which support question.
- 5
Take timed runs across all domains
Sit the 500-173 practice test in Timed Mode once each domain has had a first pass. Ask Brainy AI Assistant to explain any sizing or multitenancy question that went wrong.
Start a timed 500-173run
Who 500-173 is for
- Pre-sales engineers who scope and size FlexPod for customer proposals.
- Data center architects who plan converged infrastructure for their organization or clients.
- Implementation engineers at FlexPod partners who build what the designers specify.
Typical job titles: Data center architect · Pre-sales engineer · Solutions architect · Systems engineer · Implementation engineer
500-173 glossary
18 terms from the exam objectives and the vendor's official material, each defined in a sentence.
- ACI
- Cisco Application Centric Infrastructure: a data center network fabric that applies policy from central controllers.
- AFF
- NetApp's all-flash storage systems that run ONTAP.
- Cisco Validated Designs (CVDs)
- Tested reference designs, with step-by-step guides, that Cisco and NetApp publish for FlexPod deployments.
- Cooperative support
- The FlexPod support model in which Cisco, NetApp and the partner work one case together, whichever part failed.
- E-Series
- NetApp block-storage arrays for workloads that need high bandwidth; they do not run ONTAP.
- Fabric Interconnects
- The UCS switches that link every server to the LAN and SAN and run UCS Manager.
- FAS
- NetApp's ONTAP storage systems built on hard disks or on a mix of disk and flash.
- Hardware Compatibility List (HCL)
- Cisco's list of the operating systems, drivers and firmware supported on each UCS server.
- IMT
- NetApp's Interoperability Matrix Tool, which lists the product versions and combinations that NetApp supports.
- IOMs
- I/O modules in a UCS blade chassis that carry the blade servers' traffic up to the Fabric Interconnects.
- IP Spaces
- An ONTAP feature that gives each tenant its own IP address space and routing, so tenants can reuse the same addresses.
- MDS
- Cisco's family of Fibre Channel switches for storage networks.
- Secure multitenancy
- Sharing one FlexPod among several tenants while keeping the traffic and data of each tenant apart.
- Service profiles
- UCS definitions of a server's identity and settings, such as addresses, firmware and boot order, that are applied to physical hardware.
- Storage virtual machines (SVMs)
- Logical storage servers in NetApp ONTAP that serve data to clients and can be given to a single tenant.
- VICs
- Cisco virtual interface cards: server adapters that present many virtual network and storage interfaces to the operating system.
- Virtual port channels (vPCs)
- A link bundle from one device to two Nexus switches that act as one, so traffic survives a switch failure.
- VSANs
- Virtual SANs that split one Fibre Channel fabric into separate logical fabrics.
Related practice tests
- 300-535Automating and Programming Cisco Service Provider Solutions (SPAUTO)
- 200-901CCNA Automation (DevNet Associate)
- 200-201CCNA Cybersecurity (CyberOps Associate)
- 200-301Cisco Certified Network Associate (CCNA)
- 300-420Designing Cisco Enterprise Networks (ENSLD)